Estimation of Dynamic Viscosity for Cobalt Oxide/Glycol Nano Fluid
Author(s) -
Sanaa Ahmed Abbashar Elhassan,
Mohammed Sulieman Ali Eltoum
Publication year - 2021
Publication title -
chemical science international journal
Language(s) - English
Resource type - Journals
ISSN - 2456-706X
DOI - 10.9734/csji/2021/v30i1230267
Subject(s) - viscometer , viscosity , materials science , nano , reduced viscosity , shear rate , relative viscosity , cobalt oxide , nanoparticle , chemical engineering , cobalt , oxide , analytical chemistry (journal) , capillary action , chemistry , chromatography , composite material , nanotechnology , metallurgy , engineering
In this study the effects due to temperature and shear rate on viscosity for Co3O4/glycol based Nano fluids at different concentration of metal oxide and different temperatures were experimentally investigated. The structure of the prepared Co3O4/glycol nanoparticles was confirmed using XRD (X-Ray Diffraction) technique. All viscosity measurements were conducted using a capillary viscometer, the viscosity experiment were carried out at wide temperatures ranging between 20°C and 80°C to determine their applicability in such range. The viscosity data were collected using a programmable rhemoter. The result showed that the Co3O4 glycol exhibit increasing viscosity with increasing nanoparticle loading and decreasing viscosity with increasing temperature.