z-logo
Premium
Relationship Between the Estimated Glomerular Filtration Rate and Kidney Shear Wave Speed Values Assessed by Acoustic Radiation Force Impulse Elastography
Author(s) -
Bob Flaviu,
Bota Simona,
Sporea Ioan,
Sirli Roxana,
Popescu Alina,
Schiller Adalbert
Publication year - 2015
Publication title -
journal of ultrasound in medicine
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.574
H-Index - 91
eISSN - 1550-9613
pISSN - 0278-4297
DOI - 10.7863/ultra.34.4.649
Subject(s) - medicine , acoustic radiation force , renal function , kidney , kidney disease , urology , wave speed , elastography , ultrasound , cutoff , parenchyma , nuclear medicine , radiology , pathology , physics , mechanics , quantum mechanics
Objectives The aim of the study was to establish the relationship between the estimated glomerular filtration rate (GFR) and kidney shear wave speed values assessed by acoustic radiation force impulse (ARFI) elastography. Methods Our study included 104 patients with or without chronic kidney disease in which the kidney shear wave speed was evaluated by ARFI elastography and correlated with the estimated GFR. Five ARFI measurements were performed in the parenchyma of each kidney. A median value expressed as meters per second was calculated. Results Five valid ARFI elastographic measurements were obtained in the right kidney in all patients and in the left kidney in 97.1% of patients. The mean kidney shear wave speed values ± SD in the right and left kidneys were similar: 2.17 ± 0.81 versus 2.06 ± 0.75 m/s ( P = .30). The mean kidney shear wave speed decreased with the decrease in the estimated GFR. Statistically significant differences were obtained only when kidney shear wave speed values obtained in patients with an estimated GFR of greater than 90 mL/min/1.73 m 2 were compared to values in patients with stage 4 (estimated GFR, 15–29 mL/min/1.73 m 2 ) and stage 5 (estimated GFR, <15 mL/min/1.73 m 2 ) chronic kidney disease: 2.32 ± 0.83 versus 1.62 ± 0.75 m/s ( P = .03) and 2.32 ± 0.83 versus 1.66 ± 0.72 m/s ( P = .04), respectively. For a cutoff value of 2.26 m/s or lower, kidney shear wave speed had 86.7% sensitivity, 48.3% specificity, a 22.1% positive predictive value, and a 95.6% negative predictive value (area under the receiver operating characteristic curve, 0.692; P = .008) for predicting the presence of an estimated GFR of less than 30 mL/min/1.73 m 2 . Conclusions Kidney shear wave speed values obtained by ARFI elastography decrease with the decrease in the estimated GFR.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here