z-logo
Premium
Spatiotemporal Image Correlation and Volumetric Impedance Indices in the Neonatal Brain
Author(s) -
Schindler Tim,
Gilbert Yasmin,
Wu Linda,
Oei Ju Lee,
Welsh Alec
Publication year - 2016
Publication title -
journal of ultrasound in medicine
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.574
H-Index - 91
eISSN - 1550-9613
pISSN - 0278-4297
DOI - 10.7863/ultra.15.05022
Subject(s) - medicine , intraclass correlation , resistive index , cardiac cycle , blood flow , resistive touchscreen , diastole , perfusion , cardiology , correlation , biomedical engineering , nuclear medicine , blood pressure , mathematics , computer science , computer vision , clinical psychology , geometry , psychometrics
Objectives Changes in tissue perfusion can be critically important in the vulnerable neonate, but they are very difficult to assess at the bedside. Spatiotemporal image correlation (STIC) sonography is an exciting concept that allows assessment of blood flow by rearranging and merging multiple 2‐dimensional color images to create serial 3‐dimensional images showing regional blood flow throughout the cardiac cycle. Variations in tissue blood flow may reflect tissue impedance and perfusion. The aim of this study was to demonstrate that it is possible to use STIC images to evaluate tissue impedance in the neonatal brain. Methods Spatiotemporal image correlation data sets were acquired by cranial sonography in 19 neonates. Offline data analysis was performed by using virtual organ computer‐aided analysis. With the use of STIC images from different phases of the cardiac cycle, impedance indices were calculated, based on maximum (systolic), minimum (diastolic), and mean virtual organ computer‐aided analysis values, in the same way that resistive indices are calculated in 2‐dimensional sonography. Results Volumetric indices for tissue impedance were obtained for all neonates. Intraclass correlation coefficients (95% confidence intervals) for volumetric impedance indices were as follows: systolic/diastolic ratio, 0.793 (0.615–0.906); pulsatility index, 0.790 (0.609–0.905); and resistive index, 0.783 (0.598–0.901). Interclass correlation coefficients for image processing and analysis were as follows: systolic/diastolic ratio, 0.868 (0.692–0.947); pulsatility index, 0.904 (0.772–0.962); and resistive index, 0.914 (0.794–0.966). Conclusions This study shows that STIC data sets can be used to calculate volumetric impedance indices in the neonatal brain. Preliminary assessment shows that this technique appears reliable and allows evaluation of regional tissue impedance in the neonate.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom