“Evaluation of Friction in Orthodontics Using Various Brackets and Archwire Combinations-An in Vitro Study”
Author(s) -
Sujeet Kumar,
Shamsher Singh,
Rani Hamsa P R,
Sameer Ahmed,
Prasanthma,
Apoorva Bhatnagar,
Manreet Sidhu,
Pramod Shetty
Publication year - 2014
Publication title -
journal of clinical and diagnostic research
Language(s) - English
Resource type - Journals
eISSN - 2249-782X
pISSN - 0973-709X
DOI - 10.7860/jcdr/2014/7990.4364
Subject(s) - bracket , nickel titanium , materials science , elastomer , stainless steel wire , metallurgy , composite material , orthodontics , shape memory alloy , structural engineering , engineering , medicine
The aim of this study was to compare frictional resistance which was produced between conventional brackets (0.022 slot Otho-Organiser) and self ligating brackets (active Forestadent and passive Damon III) by using various arch wire combinations (0.016 Niti, 0.018 Niti, 0.017 x 0.025 SS and 0.019 x 0.025 SS).