NO<sub>2</sub> measurement using fiber coupled broadband LED source combining a Herriott multi-pass cell
Author(s) -
Yuan Cao,
Tian Xing,
Gang Cheng,
Kun Liu,
Guishi Wang,
Gongdong Zhu,
Xiaoming Gao
Publication year - 2019
Publication title -
acta physica sinica
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.199
H-Index - 47
ISSN - 1000-3290
DOI - 10.7498/aps.68.20190243
Subject(s) - collimated light , optics , materials science , physics , spectrometer , beam (structure) , laser
An NO 2 sensor based on a fiber coupled broadband LED source with a Herriott multi-pass cell is developed and demonstrated for calibrating aerosol absorption photoacoustic (PA) spectrometer. At first, a Herriott multi-pass cell with an effective optical path of 26.1 m is designed based on the theory of light transmission, for increasing the light absorption of NO 2 in the cell. It is difficult to obtain a high-quality beam of LED by using the conventional collimating method that enables the collimated output beam to transmit back and forth in the multi-pass cell, due to the large emitting surface and divergence angle of the LED. So, in the present work, the emission of the LED is coupled into a single model fiber, and then collimated by using a lens. The LED spectrum does not change before and after fiber coupling. The collimated beam with a central wavelength of 438.5 nm is coupled into the multi-pass cell. The output beam passing through the multi-pass cell is detected by using a spectrometer for retrieving the NO 2 concentration. Finally, an expected concentration detection limit of 1 μmol/mol (3 σ ) is achieved within 1 s acquisition time and the signal-to-noise ratio (SNR) is 40. By analyzing the result measured with 46 μmol/mol NO 2 , a measurement precision of 0.1% is achieved. In order to calibrate the aerosol absorption PA spectrometer, the NO 2 sensor and the aerosol absorption PA spectrometer based on 450 nm are used to measure different concentrations of NO 2 , simultaneously. The results show that the measured NO 2 concentration has a good linear relationship with the PA spectrum signal, and the linearity is better than 99.9%. This good linear relationship further shows the feasibility and reliability of the NO 2 sensor. The slope of calibration curve after normalizing the power is 0.95 nV/(mW·Mm -1 ). Using this calibration result, the PA signal measured with aerosol absorption PA spectrometer is transformed into the absorption coefficient. The developed NO 2 measuring system based on a broadband LED light source and Herriott multi-pass cell has the advantages of low cost, simple structure and easy use. It can be used to calibrate the aerosol absorption PA spectrometer, and also to measure NO 2 in industry.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom