Resolution of coherent field imaging technique
Author(s) -
Wenxi Zhang,
Ling Xiang,
Xinxin Kong,
Yang Li,
Weizheng Zhou,
Zhou Zhi-Shen
Publication year - 2013
Publication title -
wuli xuebao
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.199
H-Index - 47
ISSN - 1000-3290
DOI - 10.7498/aps.62.164203
Subject(s) - point spread function , optical transfer function , optics , coherent diffraction imaging , transmitter , physics , field (mathematics) , resolution (logic) , fourier transform , transfer function , function (biology) , computer science , phase retrieval , quantum mechanics , telecommunications , mathematics , artificial intelligence , channel (broadcasting) , electrical engineering , evolutionary biology , pure mathematics , biology , engineering
According to the relevant theory of optical transfer function (OTF), the OTF and point spread function of coherent field imaging technology (also known as Fourier telescopy) are derived. The formulas for calculating the resolution power of coherent field imaging system with T type and O type transmitter arrangement are given, which provides a theoretic basis of analyzing the limited angle resolution of coherent field imaging system. Based on this study, the relationship between resolutions of the coherent field imaging system with T type and O type transmitter arrangement is investigated. © 2013 Chinese Physical Society