Onedimensional imaging system for the diagnosis of the Zpinch xray radiation
Author(s) -
Xu Rong Kun,
Li Zheng Hong,
Caili Guo,
Yang Jian Lun,
Linbo Li,
Song Jun,
Ning Jiamin,
Xia Xin,
Xu Zhang
Publication year - 2003
Publication title -
wuli xuebao
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.199
H-Index - 47
ISSN - 1000-3290
DOI - 10.7498/aps.52.1203
Subject(s) - z pinch , streak , optics , scintillator , image intensifier , streak camera , pinch , physics , radiation , image resolution , resolution (logic) , plasma diagnostics , plasma , laser , detector , computer science , nuclear physics , artificial intelligence
A temporalspatial resolution system, which is composed of a slit, infra scintillator, optical fibre array, streak camera, image intensifier, etc., is constructed for the diagnosis of the Zpinch plasma. This system can effectively shield visible light and has an advantage of gaining flat response in the interested region of xray energy. The designed parameters and experimental results of gaspuff Zpinch are presented in this paper.