z-logo
open-access-imgOpen Access
Modeling of Heat Transfer in the Helical-Coil Heat Exchanger for the Reactor Facility "UNITERM"
Author(s) -
В. И. Солонин,
Anatoly Anatolyevich Satin
Publication year - 2014
Publication title -
nauka i obrazovanie
Language(s) - English
Resource type - Journals
ISSN - 1994-0408
DOI - 10.7463/1014.0727220
Subject(s) - heat exchanger , electromagnetic coil , nuclear engineering , heat transfer , materials science , mechanics , mechanical engineering , engineering , physics , electrical engineering

Circuit heat sink plays an important role in the reactor system. Therefore it imposes high requirements for quality of determining thermal-hydraulic parameters. This article is aimed at modeling of heat exchange process of the helical-coil heat exchanger, which is part of the heat sink circuit of the reactor facility "UNITERM."

The simulation was performed using hydro-gas-dynamic software package ANSYS CFX. Computational fluid dynamics of this package allows us to perform calculations in a threedimensional setting, giving an idea of the fluid flow nature. The purpose of the simulation was to determine the parameters of the helical-coil heat exchanger (temperature, velocity at the outlet of the pipe and inter-tubular space, pressure drop), and the nature of the fluid flow of primary and intermediate coolants. Geometric parameters of the model were determined using the preliminary calculations performed by the criterion equations. In calculations Turbulence models k-ε RNG, Shear Stress Transport (SST) are used. The article describes selected turbulence models, and considers relationship with wall function.

The calculation results allow us to give the values obtained for thermal-hydraulic parameters, to compare selected turbulence models, as well as to show distribution patterns of the coolant temperature, pressure, and velocity at the outlet of the intermediate cooler.

Calculations have shown that:

- maximum values of primary coolant temperature at the outlet of the heat exchanger surface are encountered in the space between the helical-coil tubes;

- higher temperatures of intermediate coolant at the outlet of the coils (in space of helicalcoil tubes) are observed for the peripheral row;

- primary coolant movement in the inter-tubular space of helical-coil surface is formed as a spiral flow, rather than as a in-line tube bank cross flow.