z-logo
open-access-imgOpen Access
Pneumocystis jirovecii Laboratuvar Tanısında Gerçek Zamanlı Polimeraz Zincir Reaksiyonu Yönteminin Değerlendirilmesi
Author(s) -
Soykan Özkoç,
Ceren Ergüden Gürbüz,
Ayça Arzu Sayıner,
Songül Bayram Delıbaş
Publication year - 2020
Publication title -
mikrobiyoloji bülteni
Language(s) - Uncategorized
Resource type - Journals
SCImago Journal Rank - 0.235
H-Index - 21
ISSN - 0374-9096
DOI - 10.5578/mb.69711
Subject(s) - pneumocystis jirovecii , bronchoalveolar lavage , medicine , parasitology , giemsa stain , polymerase chain reaction , gold standard (test) , pneumocystis pneumonia , virology , biology , pathology , human immunodeficiency virus (hiv) , gene , lung , biochemistry
Pneumocystis jirovecii is a human-specific species and causes fatal infections like P.jirovecii pneumonia (PCP) in immunocompromised persons. Although direct microscopy is the gold standard in the diagnosis of the microorganism, molecular methods such as polymerase chain reaction (PCR) are needed in non-human immune deficiency virus (HIV) immunosuppresive patients with low P.jirovecii burden. In this study, we aimed to evaluate the value of real-time PCR (Rt-PCR) in the laboratory diagnosis of P.jirovecii. Bronchoalveolar lavage (BAL) specimens of 658 patients sent to Dokuz Eylul University Hospital Central Medical Parasitology Laboratory on suspicion of PCP were included in the study. BAL fluids were evaluated for identification of P.jirovecii mitochondrial gene coding ribosomal large subunit (mtLSUrRNA) using Rt-PCR. In addition, Giemsa and Gomori's methenamine silver (GMG) staining assays were applied to all samples and nested PCR (n-PCR) assay was applied to positive samples detected by real time PCR. Ninety-two (14.3%) of these samples were positive by Rt-PCR. Of these 92 patients, 85 (92.4%) were positive with n-PCR. Only seven of the specimens had P.jirovecii cysts and trophozoites with microscopic examination. The mean cycle threshold (CT ) value of Rt-PCR positive patients was 29.7 (18.17 ≤ CT ≤ 37.96). P.jirovecii load in these patients was calculated as 2.6 x 101-6.15 x 107 copies/ml. The difference between the mean CT values of n-PCR positive and negative results was statistically significant (p< 0.01). The CT values of Rt-PCR of the samples with positive microscopy were; 18.2, 20.9, 22.2, 24.3, 24.7, 26.5, 29.7. The difference between the CT means of the samples with positive and negative microscopy was statistically significant (p< 0.05). When positive patients were grouped according to their diagnosis; the lowest mean CT value (CTmean= 24.8) was found in HIV-positive patients. On the other hand, CT values were found to be significantly lower in the organ transplantation patients (CTmean= 26.15) and in the collagen-vascular-inflammatory patient group (CTmean= 27.8). This study demonstrated that Rt-PCR was the effective method in the diagnosis of P.jirovecii in the laboratory. Conventional n-PCR method was found to be more unsuccessful than Rt-PCR in the presence of very low density organism; direct microscopy is generally found to be positive in samples with a higher burden of P.jirovecii.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here