COMPARISON OF THE COBB ANGLE MEASUREMENT BETWEEN MANUAL AND DIGITAL METHODS AMONG FIVE MILITARY HOSPITALS
Author(s) -
Chalermrit Kraturerk,
Sompob Poopitaya,
Roongrath Chitragran
Publication year - 2021
Publication title -
journal of southeast asian medical research
Language(s) - English
Resource type - Journals
ISSN - 2697-5424
DOI - 10.55374/jseamed.v5i2.88
Subject(s) - intraclass correlation , cobb , cobb angle , scoliosis , dicom , medicine , orthopedic surgery , significant difference , mean difference , nuclear medicine , medical physics , orthodontics , mathematics , radiology , statistics , surgery , reproducibility , confidence interval , genetics , biology
Background: The Cobb angle measurement of the spine is an important parameter for assessing patients with scoliosis in terms of diagnosis, treatment planning, follow-up for severity and disease progression. This angle can be obtained from a plain X-ray film in an upright posteroanterior view or can be measured from digital images. A 5° curve progression is considered clinically significant. Objective: This study aimed to compare the accuracy and difference of the Cobb angle measurements between manual and digital methods among 5 military hospitals located in the 1st area of command having orthopedic services and using different Picture Archiving and Communication (PACS). Methods: Using plain X- ray films of patients diagnosed with scoliosis, a comparative study of the Cobb angle measurement was conducted. A total of 120 images were recorded in a compact disc in the Digital Imaging and Communications in Medicine (DICOM) system and was used to install in computer systems of 5 military hospitals (Hospitals A, B, C, D, and E), and then was interpreted using each hospital digital PACS. The mean difference of 5° is considered clinically significant. The validity of measurements was analyzed using paired t- test for the mean equivalence. The reliability of one time measurement was also performed using Intraclass Correlation Coefficient (ICC). Results: Both one time and an average of three times of digital measurements among Hospitals A, B, C, D and E revealed significant differences when compared with the manual measurement (p < 0.01). However, no clinical significance of both one time and the averaged three measurements were observed when the mean difference was less than 5°. In the combined process group (Hospitals C, D and E), a significant difference of the manual and digital measurements was observed (p<0.01). However, no clinical significance using both one time and averaged three time measurements was found when the mean difference was less than 5°. The data of one time digital measurements were reliable (ICC= 0.9). Conclusion: The use of digital Cobb angle measurement is a convenient practice. A significant difference using manual and digital methods was found using both one and combined processes; however, no clinical significance was observed. One time digital measurement revealed validity as those found in three time averaged measurements.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here