Comparative field study of Rapid-Antigen Detection (RAD) with Multiplex Real Time-PCR for COVID-19 diagnosis
Author(s) -
Mr Hussan,
Fadia Waheed,
Habib Ullah,
Muhammad Khurram,
Ghadir Ali,
Maryam Shahid,
Faisal Zaman,
Abdullah Abdullah,
Asraf Hussain Hashmi
Publication year - 2022
Publication title -
pakistan biomedical journal
Language(s) - English
Resource type - Journals
eISSN - 2709-2798
pISSN - 2709-278X
DOI - 10.54393/pbmj.v5i4.397
Subject(s) - antigen , multiplex , gold standard (test) , covid-19 , immunoassay , medicine , real time polymerase chain reaction , multiplex polymerase chain reaction , virology , polymerase chain reaction , antibody , immunology , biology , disease , gene , bioinformatics , infectious disease (medical specialty) , biochemistry
RT-PCR is a gold standard test for the diagnosis of SARS-CoV2 (Covid-19) infection; however, it is an expensive, time consuming and technical demanding technique. Rapid antigen detection immunoassay (RAD) is cost-effective, quick as well as can be performed and interpreted easily. The rapid diagnosis of COVID-19 patients is essential to reduce cost and control the disease spread; however, the real world data of these tests must be validated with RT-PCR before they can be used at large scale. The objective of this study was to determine the sensitivity and specificity of PanbioTMCOVID-19 Ag-Rapid test device (Abbot) with multiplex RT-PCR. METHODS:  A total of n=3509 samples were tested for SARS-CoV-2 RAD and RT-PCR at Institute of Biomedical and Genetic Engineering, Islamabad. The rapid antigen tests were performed by PanbioTMCOVID-19 Ag-Rapid test device (Abbott) and compared with RT-PCR performed on Thermo Fisher (ABI) Quant Studio 5 using CDC 2019-nCoV RT-PCR protocol.  RESULTS: Total (n=3509), n=458 (7.60%) samples were reported positive by rapid antigen out of which n= 445 RT-PCR positive (13 false positive by rapid antigen), n=3051 (92.4%) were negative. True antigen negative tests n= 3051) were repeated with RT-PCR among these, n=25 were observed RT-PCR positive (rapid antigen false negative). The threshold cycle (CT) for the RT-PCR tests of these samples was >30. CONCLUSION: PanbioTMCOVID-19 Ag-Rapid test devices (Abbott) showed a sensitivity ratio 94.6% compared to RT-PCR. The PanbioTMCOVID-19 Ag-Rapid test device (Abbott) is reliable and can be used for screening and isolation of positive patients from the population.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here