z-logo
open-access-imgOpen Access
Comparative evaluation of dimensional stability and flexural strength of different light cured tray materials with self-cured tray material: an in-vitro study
Author(s) -
Dr Taha Attarwala,
Dr Ramandeep Dugal,
Dr Aamir Godil,
Dr Sanaa Wadwan,
Dr Pallavi Madanshetty,
Dr Arshi Kazi
Publication year - 2022
Publication title -
dentistry 3000
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.136
H-Index - 1
ISSN - 2167-8677
DOI - 10.5195/d3000.2022.179
Subject(s) - tray , flexural strength , materials science , universal testing machine , composite material , acrylic resin , mathematics , mechanical engineering , engineering , ultimate tensile strength , coating
Objectives: To carry out a comparative evaluation of dimensional stability and flexural strength of different light cured tray materials with self-cured tray material as control.Materials and methods: The study was carried out in four groups based on the different available tray materials. Group A (n=30) – light cured resin (Individo Lux-VOCO™ GmbH Germany); Group B (n=30)- light cured resin (Profibase-VOCO™ GmbH Germany); Group C (n=30)- light cured resin (Plaque Photo-Willmann and Pein™ GmbH Germany); Group D (n=30)- control group-self cured resin (Asian special instant tray material Asian Acrylates™, Mumbai, India). A digital micro-meter was used to measure the length of each specimen first at 1 hour, 24 hour and 48 hour and three readings were taken up to 0.001 decimal. The values for flexural strength of each specimen were measured using the 3-point bending technique with the help of a universal testing machine. The mean values of dimensional stability and flexural strength were calculated by the one-way ANOVA and Tukey’s post-hoc test for multiple group`s comparison.Results The mean change in length (in mm) of light cured resins samples were significantly lower than self-cured resin samples at all three time intervals. The flexural strength values of light cured resin samples-Group A (84.46±13.32 N/mm2), B (83.43±14.52 N/mm2) and C (86.80±14.73 N/mm2) was significantly higher than the self-cured resin samples group D (41.29±7.93 N/mm2)Conclusions: Light cured tray materials are more dimensionally stable and have a higher flexural strength compared to self-cured tray materials. 

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom