z-logo
open-access-imgOpen Access
Short-term effect of non-preserved cationic oil in-water ophthalmic emulsion on tear meniscus parameters of healthy individuals in a prospective, controlled pilot study
Author(s) -
Οlga E. Makri,
Iasonas Tsekouras,
Stylianos Mastronikolis,
Constantine D. Georgakopoulos
Publication year - 2021
Publication title -
medical hypothesis discovery and innovation in ophthalmology
Language(s) - English
Resource type - Journals
eISSN - 2322-4436
pISSN - 2322-3219
DOI - 10.51329/mehdiophthal1415
Subject(s) - ophthalmology , medicine , eye drop , artificial tears , tears , optical coherence tomography , emulsion , prospective cohort study , meniscus , surgery , mathematics , chemistry , biochemistry , geometry , incidence (geometry)
Background: This study investigated the effect of instilling a single drop of non-preserved cationic oil-in-water ophthalmic emulsion (Cationorm®) on the lower (LTM) and upper tear meniscus (UTM) parameters of normal eyes. Methods: In this prospective, single-center, non-randomized, controlled pilot study, optical coherence tomography was used to estimate the UTM and LTM height, depth, and cross-sectional area in participants without a history of dry eye disease. In the right eye (study eye), we instilled one drop of Cationorm® in the lower conjunctival sac. Scans of the tear menisci were acquired at baseline, before the instillation, and at 5, 15, and 30 min thereafter. Control scans of the left eye (control eye) were obtained at the same timepoints. The tear meniscus parameters of the study eye were compared with the control eye at each timepoint. Results: Twenty subjects (11 male and 9 female; mean ± standard deviation of age: 37.8 ± 10.9 years) were included in the study. Compared to the control eye, instillation of a single drop of Cationorm® resulted in significantly higher LTM parameter values and a higher UTM cross-sectional area up to 30 min after instillation (all P < 0.05). The UTM height and depth were significantly greater in the study eye than in the control eye up to 5 min (P < 0.001 and 0.007, respectively) and 15-min (P = 0.045, and 0.002, respectively) after Cationorm® instillation. In the study eye, Cationorm® resulted in a significant increase in LTM parameter values up to 30 min post-instillation (all P < 0.001). The UTM height was significantly greater up to 15 min post-instillation than at baseline. The UTM depth and area increased significantly from baseline to 5 min after instillation. Conclusions: Cationorm® seems to have a prolonged residence time on the ocular surface of healthy subjects as indicated by LTM parameters and to a lesser extent by UTM parameters. Keywords: ophthalmic emulsion, cationorm, upper tear meniscus, lower tear meniscus, spectral domain-optical coherence tomography, SD-OCT, residence time

The content you want is available to Zendy users.