Open Access
Study of Noise Annoyance and Vibration of Constructal Designed Window Air Conditioner
Author(s) -
Selva Pandian Ebenezer,
Achintya Kumar Pramanck,
K. P. Ramachandran,
Pradeep Kumar Krishnan
Publication year - 2022
Publication title -
trends in sciences
Language(s) - English
Resource type - Journals
ISSN - 2774-0226
DOI - 10.48048/tis.2022.2693
Subject(s) - air conditioning , annoyance , noise (video) , refrigerant , vibration , acoustics , heat exchanger , flammable liquid , engineering , automotive engineering , computer science , mechanical engineering , physics , artificial intelligence , image (mathematics) , loudness , waste management
Industrial, residential and commercial noise levels are to be maintained for acoustic comfort living conditions. Sound annoyance is a sensation of discontentment linked with any driving force from machines or a circumstance. It is certain that, noise can harm human hearing capacity and brain neuron cells. Novelty of this study was the design of window air conditioner with modified heat exchanger coils with phase change material and water were used as refrigerants. Noise and vibration assessment of the constructal designed window air conditioner (CDWAC) and normal window air conditioner (NWAC) with the conventional vapor compression system was carried out. The noise levels, daily exposure noise level, noise criteria levels of the developed window air conditioner was found to be satisfactory according to the British Standard 4142 and noise at work regulations 1789.
The noise criteria for the CDWAC with phase change material and water exhibited a better performance around 50 dB whereas the NWAC with vapor compression system was around 60 dB.
For normal window AC the RMS value is about 0.62 and constructal window AC is about 0.38. peak amplitude was observed as 0.346 m/s2 in the CDWAC whereas it was about 0.512 m/s2 for NWAC compressor. The amplitude of vibration is very nominal in between 2 to 2.5 s in CDWAC and the peak variation is same as in 1.5 s. Results reveal that the noise and vibration performance of the construction designed window air conditioner was better than the NWAC.
HIGHLIGHTS
The design of constructal window air conditioner was an attempt to minimize one of the disorders or imperfections in the system that is the noise level created by the air conditioner during its operation
Noise and vibration analysis of constructal designed window air conditioner was studied in comparison with the normal window air conditioner
Vibration analysis was carried out through the experimental investigation
Time domain analysis and spectral analysis of both the air conditioners were performed and the curves were plotted for better understanding of the performances of both the air conditioners in connection with vibration during operation
In sum, it is found that constructal law based design of window air conditioner performs better than the normal window air conditioner
GRAPHICAL ABSTRACT