Aging Effect on Structure, Hardness, Roughness Behavior and Bacterial Adhesion on Silver- Palladium Dental Alloy
Author(s) -
Abu Bakr El-Bediwi,
Doaa Al- Ragae,
Thoraya El-Helaly
Publication year - 2020
Language(s) - English
DOI - 10.47363/jbbr/2020(2)109
Subject(s) - alloy , palladium , materials science , vickers hardness test , surface finish , saliva , surface roughness , adhesion , metallurgy , composite material , abrasion (mechanical) , hardness , chemistry , microstructure , biochemistry , catalysis
Aging in normal saliva for different interval times make a change in internal structure (Formed phases and started base line) of Sliver- Palladium (Ag-Pd) dental alloy. Also aging in saliva for one, two and three weeks decreased Vickers hardness value, calculated maximum shear stress (τm) and roughness parameters for Sliver- Palladium alloy. Microbiological studies show the Candida spp. stuck on Sliver- Palladium alloy surface and their growth dependent on aging times.