z-logo
open-access-imgOpen Access
Shielding assessment in two computed tomography facilities in South-South Nigeria: How safe are the personnel and general public from ionizing radiation?
Author(s) -
Akintayo Daniel Omojola,
Funmilayo Ruth Omojola,
Michael Onoriode Akpochafor,
Samuel Olaolu Adeneye
Publication year - 2020
Publication title -
the asean journal of radiology
Language(s) - English
Resource type - Journals
ISSN - 2672-9393
DOI - 10.46475/aseanjr.v21i2.89
Subject(s) - kerma , electromagnetic shielding , ionizing radiation , nuclear medicine , radiation protection , effective dose (radiation) , dose rate , medicine , environmental science , medical physics , dosimetry , physics , engineering , electrical engineering , irradiation , nuclear physics
Objective: The aims of this study were to estimate the instantaneous dose rate(IDR) and annual dose rate (ADR) to radiation staff and the general public withinthe controlled and supervised areas, respectively, to determine the shieldingdesign goals (P) of the 2 CT facilities and to determine the average annual dose(AD) to radiographer/operator in the control console during CT scans.Materials and Methods: The equipment used in this study consisted of twonewly installed General Electric (GE) Revolution ACTs CT machines. Technicalparameters used were a thoracic/dorsal spine scan, which was rarely done in both facilities. A calibrated Inspector USB (S.E. International, Inc.) survey meter was positioned < 50 cm from each barrier at various points to determine the average shielded air kermaResults: The average background radiation in the 2 facilities was 0.11 ?Sv/hr. The average ADR to the controlled and supervised areas in CT1 was 0.563±0.25 and 0.369±0.11 mSv/yr, respectively. Also, the average ADR to the controlled and supervised areas in CT2 were 0.410±0.28 and 0.354±0.04 mSv/yr, respectively. The average shielding design goal to the controlled and supervised areas for CT1 was 0.00898±0.0041 and 0.0059±0.0028 mSv/Week, respectively. Similarly, the average shielding design goal for the controlled and supervised areas for CT2 was 0.0066±0.0044 and 0.0057±0.0019 mSv/Week respectively. The estimated average AD to the operator in CT1 and CT2 was 2.5 and 1.3 ?Sv, respectively.Conclusion: The average ADR and shielding design goals in the controlled and supervised areas from both CTs were within acceptable limits for radiation staff and the public.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here