z-logo
open-access-imgOpen Access
Marginal and internal fit evaluation of conventional metal-ceramic versus zirconia CAD/CAM crowns
Author(s) -
Nayana Paul,
KN Raghavendra Swamy,
MR. Dhakshaini,
S. Sowmya,
M. Meravini
Publication year - 2020
Publication title -
journal of clinical and experimental dentistry
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.481
H-Index - 23
ISSN - 1989-5488
DOI - 10.4317/jced.55946
Subject(s) - cad , cubic zirconia , ceramic , materials science , metal , dentistry , composite material , medicine , metallurgy , engineering , engineering drawing
Background The purpose of this in vivo study was to compare the marginal and internal gap widths of monolithic zirconia crowns fabricated by CAD/CAM technique and metal-ceramic crowns fabricated by conventional technique.Material and Methods 10 participants needing a single restoration were selected. Zirconia crowns using CAD/CAM technology (Group A) (n=10) and metal-ceramic crowns (Group B) (n=10) using lost wax casting technique were fabricated for each selected tooth. The marginal and internal gaps of crowns were recorded using a replica technique with light body silicone material stabilized with a regular set putty. Each replica was sectioned buccolingually and mesiodistally and then evaluated at five pre-determined sites. The points measured were PM for marginal gap, PA for axial gap, PAO for axio-occlusal transition gap and PO and PCO for occlusal gaps using a stereomicroscope at 30× magnication. The Paired Sample (t) test was used to detect significant differences between the two groups in terms of marginal and internal fit (α= 0.05).Results The mean for the marginal gap was 77.42μm (±39.5μm) for Group A compared with 95.86μm (±55.12μm) for Group B. Mean values for internal gap was 87.24 (±21.7 µm) for Group A and 132.91 µm (± 50.63 µm) for Group B. Significant differences were observed between both the groups for marginal ( p =.010) and internal ( p =.000) fit.Conclusions The CAD/CAM fabricated zirconia crowns demonstrated a better accuracy of fit when compared to metal-ceramic crowns fabricated by conventional technology. Key words: Marginal fit, Internal fit, Computer-aided design/computer-aided manufacturing (CAD/CAM).

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom