
Transient elastography: Kill two birds with one stone?
Author(s) -
Grace Lai–Hung Wong
Publication year - 2013
Publication title -
world journal of hepatology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.913
H-Index - 55
ISSN - 1948-5182
DOI - 10.4254/wjh.v5.i5.264
Subject(s) - medicine , transient elastography , gastroenterology , hepatocellular carcinoma , liver biopsy , cirrhosis , steatosis , fibrosis , fatty liver , chronic liver disease , steatohepatitis , liver disease , stage (stratigraphy) , biopsy , disease , paleontology , biology
Assessment of liver fibrosis and steatosis is crucial in chronic liver diseases in order to determine the prognosis, the need of treatment, as well as monitor disease progression and response to treatment. Liver biopsy is limited by its invasiveness and patient acceptability. Transient elastography (TE, Fibroscan(®)) is a non-invasive tool with satisfactory accuracy and reproducibility to estimate liver fibrosis and steatosis. TE has been well validated in major liver diseases including chronic hepatitis B and C, non-alcoholic fatty liver disease, alcoholic liver disease, primary biliary cirrhosis, and primary sclerosing cholangitis. As alanine aminotransferase (ALT) is one of the major confounding factors of liver stiffness in chronic hepatitis B, an ALT-based algorithm has been developed and higher liver stiffness measurements (LSM) cutoff values for different stages of liver fibrosis should be used in patients with elevated ALT levels up to 5 times of the upper limit of normal. Otherwise falsely-high LSM results up to cirrhotic range may occur during ALT flare. TE is also useful in predicting patient prognosis such as development of hepatocellular carcinoma (HCC), portal hypertension, post-operative complications in HCC patients, and also survival. Unfortunately, failed acquisition of TE is common in obese patients. Furthermore, obese patients may have higher LSM results even in the same stage of liver fibrosis. The new XL probe, a larger probe with lower ultrasound frequency and deeper penetration, increases the success rate of TE in obese patients. The median LSM value with XL probe was found to be lower than that by the conventional M probe, hence cutoff values approximately 1.2 to 1.3 kPa lower than those of M probe should be adopted. Recent studies revealed a novel ultrasonic controlled attenuation parameter (CAP) of the machine is a useful parameter to detect even low-grade steatosis noninvasively. CAP may also be used to quantify liver steatosis by applying different cutoff values. As both LSM and CAP results are instantly available at same measurement, this makes TE a very convenient tool to assess any patients who are suspected or confirmed to suffer from chronic liver diseases.