Effect of drill-induced noise on hearing in non-operated ear
Author(s) -
Seyyed Hamidreza Abtahi,
Alireza Fazel,
Mehrdad Rogha,
Mohammad Hussein Nilforoush,
Reza Solooki
Publication year - 2016
Publication title -
advanced biomedical research
Language(s) - English
Resource type - Journals
ISSN - 2277-9175
DOI - 10.4103/2277-9175.182218
Subject(s) - medicine , pure tone audiometry , otoacoustic emission , significant difference , audiology , audiometry , drill , pure tone , hearing loss , surgery , materials science , metallurgy
Background: The aim of this study was to evaluate the effect of drill-generated noise on hearing loss in non-operated ear and if any, was temporary or persistent.Materials and Methods: In this prospective clinical study, 23 patients who had undergone mastoidectomy and normal contralateral hearing were enrolled. Patients were evaluated preoperatively and postoperatively (1 and 7 days) following surgery using low and high-frequency pure tone audiometry (PTA) and low and high-frequency transient evoked and distortion product otoacoustic emission (DPOAE) testing.Results: Comparing preoperative and 1-day after surgery, PTA averages were significantly different at low frequencies, but no statistical significant differences were observed at 0.25 KHz and high-frequencies. Comparing 1-day after surgery and 7 days after surgery showed that, PTA averages at 0.5, 2 and 2 KHz were significantly different with no significant differences at the other average of thresholds in low and high frequencies; PTA average at 1 KHz was significantly different with, no significant differences at the other averages of thresholds in low and high frequencies. DPOAEs showed a significant difference preoperative and 1-day after surgery, 1-day and 7 days after, but DPOAEs were not significantly different. Transiently evoked otoacoustic emissions (TEOAEs) had a significant difference preoperative and 1-day after surgery, 1-day and 7 days after but when comparing preoperative and 7 days after surgery, TEOAEs were not significantly different.Conclusions: Drill-induced noise during ear surgery (mastoidectomy) can cause reversible changes in PTA, DPOAEs and TEOAEs in the non-operated ear