z-logo
open-access-imgOpen Access
The predictive value of the ratio of neck circumference to thyromental distance in comparison with four predictive tests for difficult laryngoscopy in obstetric patients scheduled for caesarean delivery
Author(s) -
Anahita Hirmanpour,
Mohammadreza Safavi,
Azim Honarmand,
Mahmoud Jabalameli,
Golnaz Banisadr
Publication year - 2014
Publication title -
advanced biomedical research
Language(s) - English
Resource type - Journals
ISSN - 2277-9175
DOI - 10.4103/2277-9175.142045
Subject(s) - medicine , predictive value , caesarean delivery , laryngoscopy , circumference , caesarean section , obstetrics , surgery , intubation , pregnancy , mathematics , geometry , biology , genetics
Background: Preoperative assessment of anatomical landmarks andclinical factors help detect potentially difficult laryngoscopies. The aim of the present study was to compare the ability to predict difficult visualization of the larynx from thefollowing preoperative airway predictive indices, in isolation and combination: Neck circumference to thyromental distance (NC/TMD), neck circumference (NC), modified Mallampatitest (MMT), the ratio of height to thyromental distance (RHTMD), and the upper-lip-bite test (ULBT). Materials and Methods: We collected data on657 consecutive patients scheduled for elective caesarean delivery under general anesthesia requiring endotracheal intubation and then evaluated all five factors before caesarean. An experienced anesthesiologist, not informed of the recorded preoperative airway evaluation, performed the laryngoscopy and grading (as per Cormack and Lehane′s classification). Sensitivity, specificity, and positive and negative predictive values for each airway predictor in isolation and in combination were determined. Results: Difficult laryngoscopy (Grade 3 or 4) occurred in 53 (8.06%) patients. There were significant differences in thyromental distance (TMD), RHTMD, NC, and NC/TMD between difficult visualization of larynx and easy visualization of larynx patients (P < 0.05).The main end-point area under curve (AUC) of the receiver-operating characteristic (ROC) was lower for MMT (AUC = 0.497; 95% Confidence Interval = CI,0.045-0.536) and ULBT (AUC = 0.500, 95% CI, 0.461-0.539) compared to RHTMD, NC, TMD, and NC/TMD score ([AUC = 0.627, 95% CI, 0.589-0.664], [AUC = 0.691; 95% CI, 0.654-0.726], [AUC = 0.606; 95% CI, 0.567-0.643], [AUC = 0.689;95% CI, 0.625-0.724], respectively), and the differences of six ROC curves were statistically significant (P < 0.05). Conclusion: The NC/TM Discomparable with NC, RHTMD, and ULBT for the prediction of difficult laryngoscopy in caes are an delivery

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here