z-logo
open-access-imgOpen Access
Anticoagulation dilemma in a high-risk patient with On-X valves
Author(s) -
Ami M. Karkar,
Manuel R. Castresana,
Nadine Odo,
Shvetank Agarwal
Publication year - 2015
Publication title -
annals of cardiac anaesthesia/annals of cardiac anaesthesia
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.42
H-Index - 27
eISSN - 0974-5181
pISSN - 0971-9784
DOI - 10.4103/0971-9784.154496
Subject(s) - medicine , thrombogenicity , mechanical heart , heart valve , cardiac valve , cardiology , venous thromboembolism , intensive care medicine , surgery , thrombosis
Thromboembolism continues to be a major concern in patients with mechanical heart valves, especially in those with unsatisfactory anticoagulation levels. The new On-X valve (On-X Life Technologies, Austin, TX, USA) has been reported as having unique structural characteristics that offer lower thrombogenicity to the valve. We report a case where the patient received no or minimal systemic anticoagulation after placement of On-X mitral and aortic valves due to development of severe mucosal arterio-venous malformations yet did not show any evidence of thromboembolism. This case report reinforces the findings of recent studies that lower anticoagulation levels may be acceptable in patients with On-X valves and suggests this valve may be particularly useful in those in whom therapeutic levels of anticoagulation cannot be achieved due to increased risk of bleeding.