Pseudophakic hyperopia in nanophthalmic eyes managed by a posterior chamber implantable collamer lens
Author(s) -
Kulin Kothari,
Prakash Nayak,
Bijal Kabir Mehta
Publication year - 2011
Publication title -
indian journal of ophthalmology/indian journal of ophthalmology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.542
H-Index - 51
eISSN - 1998-3689
pISSN - 0301-4738
DOI - 10.4103/0301-4738.77014
Subject(s) - medicine , dioptre , keratometer , ophthalmology , refractive error , visual acuity , intraocular lens , cataract extraction , optometry
We report a case of a bilateral posterior chamber implantable collamer lens (ICL) implantation post-clear lens extraction, to reduce the residual hyperopia, in a patient with nanophthalmic eyes. A 30-year-old female patient, keen to reduce her dependency on glasses and contact lenses, came to our refractive surgery department. Her refractive error was +12.0 and +12.5 diopters in the right and left eye, respectively, with steep corneas on keratometry and a shallow anterior chamber depth. She underwent clear lens extraction with implantation of +35.0 D and +40.0 D IOL in the right eye and left eye, respectively. Her post-operative best-corrected visual acuity was 20/30 with +8.5 D in the right eye and +6 D in the left. She underwent bilateral ICL implantation. Postoperatively after 6 months, her unaided visual acuity was 20/30 in both eyes. In conclusion, ICL implantation can be considered to correct residual hypermetropic ametropia in pseudophakic eyes when other options have limitations.