z-logo
open-access-imgOpen Access
Ocorrência de <em>Pseudomonas aeruginosa</em> em água potável
Author(s) -
Natália Maria Maciel Guerra,
Marcelo Henrique Otênio,
Marie Eliza Zamberian Silva,
Marcio Guilermetti,
Celso Vataru Nakamura,
Tânia Ueda-Nakamura,
Benetido Prado Dias Filho
Publication year - 2006
Publication title -
acta scientiarum. biological sciences
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.16
H-Index - 23
eISSN - 1807-863X
pISSN - 1679-9283
DOI - 10.4025/actascibiolsci.v28i1.1053
Subject(s) - turbidity , fecal coliform , chlorine , alkalinity , chemistry , organic matter , environmental chemistry , filtration (mathematics) , dilution , pseudomonas aeruginosa , environmental science , bacteria , microbiology and biotechnology , water quality , biology , ecology , mathematics , genetics , statistics , physics , organic chemistry , thermodynamics
Foram analisadas 413 amostras de água potável do sistema principal e do sistema secundário em Bandeirantes, Estado do Paraná, através de membrana filtrante para P. aeruginosa e bactérias heterotróficas em ágar Plate Count. Coliformes totais e fecais foram determinados pelo método dos tubos múltiplos. A qualidade físico-química da água foi determinada em termos de turbidez, pH, cloro, flúor, alcalinidade, cor, oxigênio dissolvido, dureza e matéria orgânica. Das amostras examinadas, 10,41% estavam contaminadas por P. aeruginosa, incluindo 23,53% das amostras do sistema de água secundário, e 8,56% das amostras do sistema de água principal. Somente uma amostra apresentou contagem de bactérias heterotróficas acima do nível máximo recomendado. P. aeruginosa isoladas foram testadas para sensibilidade ao cloro livre e sobreviveram a uma concentração de cloro três vezes acima da concentração mínima usada. É recomendada a determinação periódica de Pseudomonas em adição aos dados rotineiramente coletados na maioria dos sistemas de abastecimento A total of 413 samples of drinking water, taken from principal and secondary water systems in the municipality of Bandeirantes, state of Paraná, southern Brazil, were analyzed through membrane filtration for P. aeruginosa and on Plate Count agar for heterotrophic bacteria. Total and fecal coliforms were determined by multiple dilution tube methods. Turbidity, pH, chlorine, fluoride, alkalinity, color, dissolved oxygen, hardness and organic matter were also measured. Of the 413 samples examined, 10.41% were contaminated by P. aeruginosa, including 23,53% of the water from secondary water system, 8,56% of the water from principal water system. No coliform was found in any of the samples. One sample counted above the maximum heterotrophic bacteria level permitted. P. aeruginosa isolated from the water samples were tested for chlorine sensitivity and survived up to three times the minimum chlorine concentration used. It is desirable that Pseudomonas enumeration be performed periodically, in addition to data routinely collected by most water supply system

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here