z-logo
open-access-imgOpen Access
Impact of coronary bifurcated vessels flow-diameter scaling laws on fractional flow reserve based on computed tomography images (FFRCT)
Author(s) -
Na Li,
AUTHOR_ID,
Bao Li,
Yixiang Feng,
Junling Ma,
Liyuan Zhang,
Jian Liu,
Youjun Liu,
AUTHOR_ID
Publication year - 2022
Publication title -
mathematical biosciences and engineering
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.451
H-Index - 45
eISSN - 1551-0018
pISSN - 1547-1063
DOI - 10.3934/mbe.2022145
Subject(s) - fractional flow reserve , coronary artery disease , scaling , medicine , nuclear medicine , mathematics , flow (mathematics) , computed tomography , cardiology , geometry , physics , myocardial infarction , radiology , coronary angiography
Objective To explore the influence of the blood flow-diameter scaling laws of $ \mathrm{Q}\mathrm{\alpha }{\mathrm{D}}^{3} $, $ \mathrm{Q}\mathrm{\alpha }{\mathrm{D}}^{2.7} $ and $ \text{Q}\alpha \text{D}{}^{7}\!\!\diagup\!\!{}_{3}\; $ on the numerical simulation of fraction flow reserve based on CTA images and to find the optimal exponents. Methods 1) 26 patients with coronary artery disease were screened according to the inclusion criteria; 2) Microcirculation resistance (R m ) was calculated under the 3, 2.7 and 7/3 power of the flow-diameter scaling law, which were recorded as 3R m , 2.7R m and 7/3R m , respectively; 3) 3R m , 2.7R m and 7/3R m were used as exit boundary conditions to simulate FFRCT, quoted as 3FFRCT, 2.7FFRCT and 7/3FFRCT, respectively; 4) The correlation and diagnostic performance between three kinds of FFRCT and FFR were analyzed. Results The p-values of comparing 3Rm, 2.7Rm and 7/3Rm with FFR were 0.004, 0.005 and 0.010, respectively; the r value between 7/3FFRCT and FFR (0.96) was better than that of 3FFRCT (0.95) and 2.7FFRCT (0.95); the 95% LoA between 7/3FFRCT and FFR (-0.08~0.11) was smaller than that of 3FFRCT (-0.10~0.12) and 2.7FFRCT (-0.09~0.11); the AUC and accuracy of 7/3FFRCT [0.962 (0.805-0.999), 96.15%] were the same as those of 2.7FFRCT [0.962 (0.805-0.999), 96.15%] and better than those of 3FFRCT [0.944 (0.777-0.996), 92.3%]. The prediction threshold of 7/3FFRCT (0.791) was closer to 0.8 than that of 3FFRCT (0.816) and 2.7FFRCT (0.787). Conclusion The blood flow-diameter scaling law affects the FFRCT simulation by influencing the exit boundary condition R m of the calculation. With $ Q\alpha D{}^{7}\!\!\diagup\!\!{}_{3}\; $, FFRCT had the highest diagnostic performance. The blood flow-diameter scaling law provides theoretical support for the blood flow distribution in the bifurcated vessel and improves the FFRCT model.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here