Operation of an inverting <i>DC-DC </i>converter with charge pumping and <i>LDO </i>in the <i>LM </i>27762 microcircuit
Author(s) -
В. К. Битюков,
В. А. Петров,
А. А. Сотникова
Publication year - 2019
Publication title -
vestnik koncerna vko «almaz - antej»
Language(s) - English
Resource type - Journals
ISSN - 2542-0542
DOI - 10.38013/2542-0542-2019-1-35-43
Subject(s) - voltage , capacitor , physics , charge pump , electrical engineering , voltage drop , power (physics) , charge (physics) , control theory (sociology) , engineering , computer science , quantum mechanics , control (management) , artificial intelligence
The paper focuses on the study of operation of an inverting DC-DC converter with charge pumping and LDO, which are the part of the combined bipolar secondary power supply LM 27762. The measurements covered two modes amply included in the range of normalized parameters with input voltages equal to 3.5 and 5.5 V, and output voltages 1.8 and 4.9 V, respectively, as well as the mode with an input voltage of 5.0 V and an output voltage 4.7 V, with a difference in the input and output voltage not exceeding the normalized limit of the voltage drop across LDO . Pulsations of voltages were measured at various load currents from 15 to 250 mA at the positive and negative poles of the flying capacitor, at the output of the charge pumping system and, in the latter case, also at the output of the microcircuit. Based on the results obtained, it was shown for the first time how at low load currents up to about 100 mA the charge pumping system operates in the burst mode, and at higher currents, it operates in the charge pumping mode with a constant frequency