Comparative evaluation of root canal preparation using Wave One and Reciproc Systems
Author(s) -
Sînziana Adina Scărlătescu,
Paula Perlea,
Irina-Maria Gheorghiu,
Cătălin Nicolae Rolea
Publication year - 2017
Publication title -
romanian journal of stomatology
Language(s) - English
Resource type - Journals
eISSN - 2069-6078
pISSN - 1843-0805
DOI - 10.37897/rjs.2017.4.5
Subject(s) - root canal , significant difference , materials science , dentistry , orthodontics , mathematics , medicine , statistics
Aim. The aim of this study was to assess the preparation of root canals using single-file instruments Wave One (Densplay-Sirona) and Reciproc (VDW Gmbh). Materials and methods. Forty lower mesial and distal root canals were divided into 4 groups (n=10) according to shaping technique; mesial roots were prepared using Reciproc 25 and WaveOne Primay and distal root using Reciproc 40 and Wave One Large respectively. Pre- and post-instrumented radiographs were taken to examine and compare the cross-sectional shape of the canals at 3, 6 and 9 mm. Results. Wave One led to bigger diameters especially at 9 mm, the difference being of 0,22 mm versus Reciproc 25 and 0,14 mm versus Reciproc 40. Conclusions. The Wave One system produced a bigger tapered root canal preparation versus the Reciproc system.