Preparation of an agglomerated ion chromatographic stationary phase with 2,3-ionene and its application in SO 4 2- analysis
Author(s) -
Muhua Wang,
Junwei Liu,
Zhongping Huang,
Jiajie Zhang,
Yan Zhu
Publication year - 2015
Publication title -
sepu/chinese journal of chromatography
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.171
H-Index - 19
eISSN - 1872-2059
pISSN - 1000-8713
DOI - 10.3724/sp.j.1123.2015.02052
Subject(s) - polystyrene , fourier transform infrared spectroscopy , divinylbenzene , chemistry , analytical chemistry (journal) , chromatography , scanning electron microscope , phase (matter) , electrolyte , ion exchange , ion exchange resin , packed bed , detection limit , ion , materials science , copolymer , polymer , chemical engineering , inorganic chemistry , organic chemistry , styrene , engineering , composite material , electrode
The poly-electrolyte cation functional group of 2,3-ionene was synthesized with tetramethyl ethylenediamine and 1,3-dibromopropane as the raw materials. Multiporous polystyrene-divinylbenzene microsphere particles (PS-DVB) were produced by swelling method with polystyrene as seeds and sulfonated. Then the 2,3-ionene was bonded on the sulfonated multi-porous polystyrene-divinylbenzene microsphere particles by agglomeration to get the agglomerative ion-exchange stationary phase. After optimizing the synthetic conditions, the new stationary phase was characterized by the techniques including scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR) and elemental analysis. The chromatographic column was packed by slurry method and applied in the analysis of SO4(2-) with a conductivity detector. SO4(2-) and other six common anions including F-, Cl-, NO2(-), Br-, NO3(-), PO4(3-), were separated and analyzed rapidly on the self-regulating chromatographic column within 8 min. The linear range was from 0.5 to 50 mg/L with correlation coefficient (r) of 0.9992. The LOD was 0.04 mg/L with S/N of 3. The relative standard deviations (RSDs, n = 6) were 2.4% and 3.1% for the peak area and retention time, respectively. The recoveries were between 99.2% and 101.8%. The retention times of SO4(2-) did not change significantly after long time use of the self-regulating chromatographic column. The self-regulating chromatographic column is suitable for the detection of SO4(2-) in complex matrix samples.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here