z-logo
open-access-imgOpen Access
Effect of Fire on Prefabricated Concrete Beam Column Connections
Author(s) -
Ch.Subramanyam Teja,
Tej Sai Moturu,
G.Yaswanth Kumar,
Haroon Ali Khan
Publication year - 2019
Publication title -
international journal of recent technology and engineering
Language(s) - English
Resource type - Journals
ISSN - 2277-3878
DOI - 10.35940/ijrte.b2092.078219
Subject(s) - precast concrete , column (typography) , structural engineering , beam (structure) , connection (principal bundle) , joint (building) , materials science , fire performance , composite material , engineering , fire resistance
The objective of this work is to study the performance of the beam column connections in precast structures exposed to fire. Three different connections were considered for the study. The first one is monolithic and the remaining two are precast specimens joined through hybrid and corbel connections. This study is carried out in two phases. The first part of this study is experimental investigation of three beam-column specimens subjected to axial load until failure. The second part is experimental investigation of the beam-column specimens exposed to fire and axial load. The results suggest that irrespective of the fire, among the monolithic, hybrid and corbel connections of beam-column specimens, the specimen with corbel connection has the best performance in terms of toughness of the joint

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here