z-logo
open-access-imgOpen Access
The effect of compression design elements for the development of theater-Tell caused by the subway movement
Author(s) -
Krzysztof Kozioł,
Waldemar Bzduła
Publication year - 2014
Publication title -
budownictwo i architektura
Language(s) - English
Resource type - Journals
eISSN - 1899-0665
pISSN - 2544-3275
DOI - 10.35784/bud-arch.1899
Subject(s) - octave (electronics) , movement (music) , compression (physics) , structural engineering , computer science , octave band , sensitivity (control systems) , object (grammar) , architectural engineering , engineering , acoustics , artificial intelligence , materials science , physics , composite material , electronic engineering
The choice of building design solutions in terms of their resistance to the influence of dynamic performance often requires a full analysis of the time. The study contains a comparison of the response of the building made in two alternative technologies: traditional concrete and mixed concrete with partial compression on the force caused by the movement of the subway in a tunnel located under the object. The building answer is understood in the sense of the influence on the building (the internal forces) as well as people staying in it (the RMS value in one-third octave 1/3 octave bands). As from numerical analysis for the analyzed types of structures, the best solution cannot be unambiguously determined. In the object the regions characterized by different dynamic "sensitivity" dependent on the choice of the type of technology used to build the elements of the structure.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here