z-logo
open-access-imgOpen Access
RESULTS OF OPERATIONS IN COLON SURGERY WITH USAGE OF LAPAROSCOPIC TECHNIQUE AND ROBOTIC ASSISTANCE
Author(s) -
О Э Карпов,
Юрий Михайлович Стойко,
А. В. Максименков,
И В Степанюк,
В А Назаров,
А Л Левчук
Publication year - 2016
Publication title -
koloproktologiâ
Language(s) - English
Resource type - Journals
eISSN - 2686-7303
pISSN - 2073-7556
DOI - 10.33878/2073-7556-2016-0-1-40-47
Subject(s) - medicine , diverticular disease , inferior mesenteric artery , surgery , robotic surgery , ligature , laparoscopic surgery , colorectal cancer , lymphadenectomy , da vinci surgical system , laparoscopy , general surgery , cancer
The analysis of short-term results of 117 laparoscopic and 16 robotic-assistant colon surgeries, performed in NMSC N.I.Pirogov between January 2011 and May 2015 was undertaken. There were 90 resections for colon cancer, 31 for diverticular disease and one for megacolon. Also results of 11 reconstructive operation after Hartmann procedure was investigated. In 74 cases of cancer operation were performed with mesocolonectomy and central vessels ligature. In 16 patients sceletization of inferior mesenteric artery and paraortal lymphadenectomy was performed. Morbidity rate was 11,3 % among all patients. The use of robotic technology in colon surgery is not an optimal option due to low cost effectiveness and prolonged operating time comparing to those after routine laparoscopic procedures.