Analisis Keselamatan Radiasi Tindakan Radiologi Intervensional dan Kateterisasi Jantung Vaskular di Cath-Lab Room RSUP Dr. Sardjito
Author(s) -
Fransiska Dian,
Bagaswoto Poedjomartono,
Toto Trikasjono
Publication year - 2015
Publication title -
jurnal radiologi indonesia
Language(s) - English
Resource type - Journals
eISSN - 2656-5803
pISSN - 2443-1745
DOI - 10.33748/jradidn.v1i1.2
Subject(s) - cath lab , medicine , radiation exposure , nuclear medicine , interventional radiology , radiation dose , radiation protection , cardiac catheterization , effective dose (radiation) , radiology , dose rate , medical physics , surgery , myocardial infarction , conventional pci
Background: Attention control in interventional radiology is not yet optimal if compared with diagnostic radiology, but the risk of radiation in interventional radiology is greater than the diagnostic radiology.Objective: To evaluate the level of radiation safety measures by conducting analysis on interventional radiology and vascular cardiac catheterization both therapy and diagnosis in Cath-Lab Room, especially in the Cath-Lab Room 2 of Radiology Unit, RSUP Dr. Sardjito.Materials and methods: Evaluation is done on the structural design of retaining, the leakage rate of X-ray machine, the environmental rate of radiation exposure and dose of radiation workers by comparing between the data with theory.Results: Most of the thick primary and secondary structural barrier has a thickness sufcient although there are still some parts are less. Average of environmental radiation exposure rate is 0,01664 ?R/hr. Then, average of radiation leak rate is 9,225 mR/hr. The average dose received by the doctors and assistants are still far from 20 mSv/year as Dose Value Limit, that is 19,2242 ?Sv/measures for physicians and 9,403 ?Sv/measures for the assistant. The number of measure in the Cath-Lab Room 2 so as not to exceed the NBD 20 mSv/year is a 1.040 measure by doctor and 1.305 act by assistant.Conclusions: In general, the examination room and X-ray machine in Cath Lab Room 2 of Radiology Unit, RSUP Dr. Sardjito Yogyakarta is in a safe condition to operate. Designing of structural barrier, control of environmental radiation exposure rates and the rate of leakage of X-ray machine, and the use of personal protection equipment can reduce radiation dose of Cath-Lab Room 2 sta? in to the lowest possible value so as to ensure the safety of sta? and the community around the Cath-Lab Room 2.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom