Anterior clinoid process and optic strut in Koreans
Author(s) -
Hye Yeon Lee,
In Hyuk Chung,
Byoung Young Choi,
KyuSung Lee
Publication year - 1997
Publication title -
yonsei medical journal/yonsei medical journal
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.702
H-Index - 63
eISSN - 1976-2437
pISSN - 0513-5796
DOI - 10.3349/ymj.1997.38.3.151
Subject(s) - anterior clinoid process , optic canal , basal (medicine) , cavernous sinus , anatomy , process (computing) , medicine , optic nerve , computer science , insulin , operating system
The anterior clinoid process and the optic strut are often removed during operation on the anterior part of the cavernous sinus. Therefore it is important for neurosurgeons to verify their dimensions and variations. The purpose of this study was to investigate the dimension and the variation of the anterior clinoid process and to describe the locational variation of the optic strut. Seventy-three skulls of Korean adults were used. The average length, basal width and thickness of the anterior clinoid process were 9.18 +/- 1.55, 9.63 +/- 1.49 and 5.32 +/- 1.07 mm, respectively. The average thickness of the optic strut was 2.9 +/- 1.15 mm and it was commonly attached to anterior two-fifths of the anterior clinoid process. The complete caroticoclinoid canal was observed in 4.1%, however it was incomplete in 11.6%. The incidence of a caroticoclinoid canal in Koreans was relatively low compared with other races.