Electrochemical behavior of stainless steel alloys used for medical and dental applications as a function of exposure to 0.9% NaCl and sterilization
Author(s) -
Cecília Alves de Sousa,
Carolina Ferrairo DanielettoZanna,
Thamara Beline,
Gustavo Zanna Ferreira,
Leonardo Pérez Faverani,
Valentim Adelino Ricardo Barão,
Wirley Goncalves Assunção
Publication year - 2021
Publication title -
research, society and development
Language(s) - English
Resource type - Journals
ISSN - 2525-3409
DOI - 10.33448/rsd-v10i5.13544
Subject(s) - dielectric spectroscopy , corrosion , materials science , surface roughness , sterilization (economics) , polarization (electrochemistry) , scanning electron microscope , metallurgy , electrochemistry , surface finish , autoclave , oxide , composite material , electrode , chemistry , economics , monetary economics , foreign exchange market , foreign exchange
This study evaluated the effect of disinfection procedures and exposure to 0.9% NaCl solution cycles during sterilization, on the electrochemical, physical and chemical properties of different stainless steel alloys used in the biomedical field. Discs of F899 XM16, F899 303, and F899 420B alloys were cleaned with enzymatic detergent followed by 20 cycles of autoclave sterilization. Electrochemical tests were performed including open circuit potential, electrochemical impedance spectroscopy, and potentiodynamic polarization tests in 0.9% NaCl (n=5). Surface characterization was performed using scanning electron microscopy (SEM), energy dispersive spectroscopy, and surface roughness and microhardness both before and after the electrochemical test. Quantitative data were analyzed with a significance level of 5%. The corrosion current density and corrosion potential of the alloys did not present statistical differences. The capacitance values of the three oxide layers, polarization resistance, and impedance of Warburg were similar among the alloys. Considering the topography, surface roughness increased for all alloys in the post-corrosion period. The stainless steel alloys analyzed were negatively affected at the electrochemical behavior, corrosion kinetics, and surface characterization after the 0.9% NaCl solution and the autoclave sterilization cycles, confirming the need for regular exchanges of surgical instruments and drills used in medical and dental implantology.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here