z-logo
open-access-imgOpen Access
Arterial and end-tidal Carbon Dioxide Tension Changes during Spinal Anaesthesia in Upper Abdominal Laparoscopic Surgeries: A Comparison with General Anaesthesia
Author(s) -
Abdullah Al Masum,
MR Alam,
Mozibul Haque,
Rubina Yasmin,
Shah Newaz H Khan
Publication year - 2018
Publication title -
journal of bangladesh college of physicians and surgeons
Language(s) - English
Resource type - Journals
eISSN - 2309-6365
pISSN - 1015-0870
DOI - 10.3329/jbcps.v37i1.39282
Subject(s) - medicine , anesthesia , pneumoperitoneum , general anaesthesia , arterial blood , lumbar , urinary retention , surgery , laparoscopy
Nowadays, laparoscopic surgeries are being performed under subarachnoid block (SAB) safely. Aims: This study was to compare the arterial and end-tidal carbon dioxide (CO2) tension changes during spinal and general anaesthesia (GA) in CO2 pneumoperitoneum for upper abdominal laparoscopic surgeries. Settings and Design: This was a prospective randomized comparative clinical study. Materials and Methods: Eighty patients posted for upper abdominal laparoscopic surgeries were randomly allocated to two groups either to receive standard GA or lumbar SAB. Results: The demographic profiles of both the groups were comparable. The PaCO2 was increased gradually and sustained at its peaks within 20±4.37 minutes in both the groups. The mean±SD revealed to be higher in Group B (41.5500±2.1315) than Group A (40.8460±2.1136), but the difference between the two was not statistically significant (P=0.6142). There was a gradual increase in ETCO2 over the initial 10±2.07 minutes and reached a plateau within 20±5.74 minutes in both the groups and declined faster after deflation of pneumoperitoneum in SAB group. The mean±SD was found to be higher in Group B (33.923±1.642) than Group A (33.408±1.772), but it was also not statistically significant (P=0.4492). The difference of the arterial blood pH between the groups was not statistically significant. Three (7.5%) patients developed transient urinary retention and 2 (5%) patients suffered from post-dural puncture headache in SAB group. Conclusions: Arterial and end-tidal CO2 tension changes during upper abdominal laparoscopic surgery under SAB remain within physiological limit and comparable to the CO2 tensions under GA. However, per-operative complications in SAB are greater, while it is lesser in postoperative period in comparison to GA. SAB may be adopted in ASA physical status I patients with proper preoperative counselling. J Bangladesh Coll Phys Surg 2019; 37(1): 13-18  

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom