z-logo
open-access-imgOpen Access
Bioengineering a Cadmium Sensing Green Fluorescent Protein based Whole-Cell Biosensor from Pseudomonas aeruginosa
Publication year - 2020
Publication title -
proceedings international
Language(s) - English
Resource type - Journals
ISSN - 2668-6384
DOI - 10.33263/proceedings21.028028
Subject(s) - cadmium , biosensor , green fluorescent protein , chemistry , cadmium chloride , escherichia coli , fluorescence , cloning (programming) , reporter gene , strain (injury) , cloning vector , biochemistry , recombinant dna , microbiology and biotechnology , gene , biology , vector (molecular biology) , gene expression , physics , organic chemistry , anatomy , quantum mechanics , computer science , programming language
Heavy metal toxicity remediation is a major issue due to the increase in industrial waste production, with cadmium being one of the major pollutants. An approach involving homologous cloning was made to bioengineer a microbial cadmium biosensor from a strain of Pseudomonas aeruginosa. The promoter pCadR from P. aeruginosa was cloned into a vector pEGFP-N2. Gibson assembly cloning method was chosen considering the several advantages it holds over the traditional cloning techniques. Escherichia coli DH5 alpha strain was used as the host cell, which on sensing cadmium, produced fluorescence using the reporter gene called green fluorescent protein (GFP). The clone, pEGFP-N2CadR, was subjected to increasing concentrations of cadmium chloride to determine the sensitivity. It was observed that pEGFP-N2CadR responded well to micromolar concentrations of cadmium chloride, and hence it may be used to detect low concentrations of cadmium. To determine the specificity of the sensor, it was also tested with lead nitrate and copper sulfate solutions. It was determined that the biosensor had non-specific interactions with other metals. The interaction of the promoter with the metals was weak as compared to previous studies, and this was attributed to slight variations and mutations observed in the promoter sequence following subsequent rounds of sequencing. As the fluorescent intensities of the sensor in response to the metals were not highly distinguishable, this biosensor was not classified as an effective cadmium sensor. Further studies for determining the promoter interaction and affinity towards various metals at varying concentrations are required to validate the results obtained.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here