Comparative Study on Multistorey Building with And Without Floating Columns
Author(s) -
Shubham Mandwale,
Nikhil Pitale
Publication year - 2020
Publication title -
international journal of scientific research in science and technology
Language(s) - English
Resource type - Journals
eISSN - 2395-602X
pISSN - 2395-6011
DOI - 10.32628/ijsrst207387
Subject(s) - column (typography) , software , structural engineering , ground floor , base (topology) , displacement (psychology) , engineering , computer science , civil engineering , mathematics , connection (principal bundle) , psychology , mathematical analysis , psychotherapist , programming language
Modern construction techniques and good architectural views of building come with the concept of floating column. FC gives good architectural views to the structure also for the space requirement for parking or movements of vehicles floating column is delivered at the ground floor. Two models of six storey building structure with FC and structure with regular columns for the comparative study on the parameters such as flat displacement, storey drift, time period and base shear. RSA has been completed using ETABS 2016 software.