Open Access
МЕТОД ВИЗНАЧЕННЯ ХОЛОДОПРОДУКТИВНОСТІ ТЕРМОТРАНСФОРМАТОРА ЗА МАКСИМАЛЬНИМ ТЕМПОМ ПРИРОЩЕННЯ ТЕРМОЧАСОВОГО ПОТЕНЦІАЛУ ОХОЛОДЖЕННЯ ПОВІТРЯ
Author(s) -
Andrii Radchenko
Publication year - 2018
Publication title -
avacìjno-kosmìčna tehnìka ì tehnologìâ/avìacìjno-kosmìčna tehnìka ta tehnologìâ
Language(s) - English
Resource type - Journals
eISSN - 2663-2217
pISSN - 1727-7337
DOI - 10.32620/aktt.2018.4.07
Subject(s) - refrigeration , cooling capacity , transformer , environmental science , cooling load , heat load , air cooling , nuclear engineering , air conditioning , electrical engineering , mechanical engineering , engineering , thermodynamics , voltage , physics
It is proved a possibility of using the thermohour cooling potential method, developed by the author, for defining the installed (design) refrigeration capacity of term transformer (refrigeration machine), providing a maximum rate of thermo-hour cooling potential increasing according to the current climatic conditions for a definite period of operation.It is proposed to define the effect, gained due to cooling air, in particular at the inlet of GTU, depends on duration and depth of cooling, by thermohour potential ÕS,°С·h, as air temperature decrease Δta multiplied by duration τ of GTU operation at decreased temperature: ÕS = ∑(Δta ∙°τ), which to some extent characterizes heat load on the cooling system.It is shown that taking into consideration a different rate of annual thermohour cooling potential arising with increasing the installed refrigeration capacity of term transformer, caused by changing the heat load according to current climatic conditions during a year, it is necessary to choose such design heat load on the air cooling system (refrigeration capacity of term transformer) that provides a maximum value of annual thermohour cooling potential or close it with relatively high rates of its increasing. To define the installed refrigeration capacity, providing a maximum rate of annual thermohour cooling potential increasing, it is analyzed the dependence of annual thermohour cooling potential related to the installed refrigeration capacity of term transformer, from the installed refrigeration capacity of term transformer. As a result of the investigation, it is proposed the method of defining the design heat load (installed refrigeration capacity) of term transformer with maximum rates of increasing thermohour cooling potential, as a further development of methodology of rational designing of them transformers for combustion engine inlet air cooling on the base of thermohour potential, developed by author