Combination of the gamma emission tomography and the virtual point-detector methods for calculating radioactive waste drum by non-destructive assays
Author(s) -
Huỳnh Đình Chương,
Tran Minh Sang,
Luu Gia Thien,
Vo Xuan Huyen,
Trần Thiện Thanh
Publication year - 2020
Publication title -
khoa học và công nghệ: tự nhiên
Language(s) - English
Resource type - Journals
ISSN - 2588-106X
DOI - 10.32508/stdjns.v2i6.884
Subject(s) - drum , radionuclide , detector , radioactive waste , tomography , gamma ray , nuclear medicine , materials science , nuclear engineering , radiochemistry , physics , nuclear physics , chemistry , engineering , optics , mechanical engineering , medicine
In this study, the gamma emission tomography and the virtual point-detector method were combined to calculate the efficiency of the radionuclide inside the radioactive waste drum. Therefore, the radioactivity of the radionuclide inside the waste drum has been calculated. The results showed that the source location was determined by the gamma emission tomography for good results with the experimental value. The discrepancies between measured and true activity were smaller than 13% for the sand matrix.