Malposition of Central Venous Catheter Inserted under Ultrasound Guidance in Intensive Care Unit: A Case Series
Author(s) -
Niraj Kumar Keyal,
Sumal Thapa,
Pooja Adhikari,
Sanjeeb Kumar Yadav
Publication year - 2020
Publication title -
journal of nepal medical association
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.176
H-Index - 19
eISSN - 1815-672X
pISSN - 0028-2715
DOI - 10.31729/jnma.4655
Subject(s) - medicine , central venous catheter , catheter , subclavian vein , internal jugular vein , surgery , complication , intensive care unit , ultrasound , radiology , intensive care medicine
Malposition of central venous catheter tip inserted into the subclavian and internal jugular vein is a rare unavoidable complication that can be decreased if inserted under ultrasound guidance. We report case series of three patients, two of subclavian and another of internal jugular inserted central venous catheter, in which the catheter malpositioned into ipsilateral internal jugular and subclavian vein respectively but had no effect on patient management. From this, we want to emphasize that the effect of malposition of central venous catheter tip depends upon the indication for which central venous catheter was inserted; it can be detected bedside by ultrasound and flush test.