REDUCING VIBRATIONS OF ELECTRIC CENTRIFUGAL SUBMERSIBLE PUMP THROUGH INSTALLATION OF THE DYNAMIC DAMPER
Author(s) -
M. V. Gabdrakhimov,
А. С. Галеев,
Г. И. Бикбулатова,
С. Л. Сабанов,
K. R. Fakhrieva
Publication year - 2016
Publication title -
izvestiâ vysših učebnyh zavedenij. neftʹ i gaz
Language(s) - English
Resource type - Journals
ISSN - 0445-0108
DOI - 10.31660/0445-0108-2016-4-18-23
Subject(s) - damper , vibration , string (physics) , process (computing) , engineering , component (thermodynamics) , unit (ring theory) , control theory (sociology) , computer science , structural engineering , mechanical engineering , acoustics , physics , mathematics , mathematics education , control (management) , quantum mechanics , artificial intelligence , thermodynamics , operating system
In the process of ESPs operation there often appear intense vibrations, leading to «a flight». For long-time operation of the unit used as a component of the drill string, it is desirable to keep it at rest. One way to accomplish this is to connect the unit with a damper that can reduce the fluctuations. The article considers the most optimal option of such connection, and the method of calculating the parameters enabling to significantly reduce the unit vibrations amplitude that will favorably influence the duration of its operation.