z-logo
open-access-imgOpen Access
Model-Based Insulin Sensitivity for Early Diagnosis of Sepsis in Critical Care
Author(s) -
Wan Fadzlina Wan Muhd Shukeri,
Azrina Ralib,
Ummu Khultum Jamaludin,
Mohd Basri Mat-Nor
Publication year - 2017
Publication title -
international medical journal malaysia/iium medical journal malaysia
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.139
H-Index - 9
eISSN - 2735-2285
pISSN - 1823-4631
DOI - 10.31436/imjm.v16i1.1157
Subject(s) - medicine , sepsis , glycemic , receiver operating characteristic , biomarker , insulin sensitivity , critically ill , gastroenterology , diabetes mellitus , insulin , area under the curve , insulin resistance , endocrinology , biochemistry , chemistry
Currently, it is almost impossible to diagnose a patient at the onset of sepsis due to the lack of real-time metrics with high sensitivity and specificity. The purpose of the present study is to determine the diagnostic value of model-based insulin sensitivity (SI) as a new sepsis biomarker in critically ill patients, and compare its performance to classical inflammatory parameters. Materials and method: We monitored hourly SI levels in septic (n=19) and non-septic (n=19) critically ill patients in a 24-hour follow-up study. Patients with type I or type II diabetes mellitus were excluded. SI levels were calculated by a validated glycemic control software, STAR TGC (Stochastic TARgeted Tight Glycemic Controller) (Christchurch, NZ). STAR TGC uses a physiological glucose-insulin system model coupled with stochastic models that capture SI variability in real time. Results: The median SI levels were lower in the sepsis group than in the non-sepsis group (1.9 x 10-4 L/mU/min vs 3.7 x 10-4 L/mU/min, P <0.0001). The areas under the receiver operating characteristic curve (AUROC) of the model-based SI for distinguishing non-sepsis from sepsis was 0.911, superior to white cells count (AUROC 0.611) and temperature (AUROC 0.618). The optimal cut-off value of the test was 2.9 x 10-4 L/mU/min. At this cut-off value, the sensitivity and specificity was 88.9% and 84.2%, respectively. The positive predictive value was 84.2%, while the negative predictive value was 88.9%. Conclusion: The early and relevant decrease of SI in sepsis suggests that it might be a promising novel biomarker of sepsis in critical care. Low SI is diagnostic of sepsis, while high SI rules out sepsis, and these may be determined non-invasively in real-time from glycemic control protocol data.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here