z-logo
open-access-imgOpen Access
Effectiveness of Resuscitation Device when Intubating Suspected COVID-19 Patient at Emergency and Trauma Department
Author(s) -
Zainul Ikhwan Ahmad Khusairi
Publication year - 2021
Publication title -
international journal of human and health sciences
Language(s) - English
Resource type - Journals
ISSN - 2523-692X
DOI - 10.31344/ijhhs.v5i0.305
Subject(s) - intubation , medicine , emergency department , personal protective equipment , medical emergency , resuscitation , emergency medicine , covid-19 , health care , anesthesia , nursing , disease , pathology , infectious disease (medical specialty) , economics , economic growth
The rapid spread of COVID-19 had expanded into a pandemic, and thousands of medical staff had been infected worldwide. Thus, the access to personal protective equipment (PPE) for health workers had become a key concern. PPE was essential in providing a physical barrier between microorganism and health care providers. In the case of cardiac arrest, the use of a resuscitation device as PPE had provoked various reactions and complaints from physicians.Objective: To determine the effectiveness of the use of an intubation box and ergonomic screening booth as a device during intubation procedures on positive COVID-19 patients in the Department of Emergency and Trauma at Taiping Public Hospital.Methods: The study was designed as a single-blind, prospective, randomized study and was approved by the committee at study location setting. Physicians selected had been given three days of training related to the use of the device as one of the PPE, before being used on patients. The procedure was carried out on three patients with unclear history of COVID-19who required intubation. The time given for each intubation procedure was 5 to10 seconds with a maximum of three attempts for each patient.Results: The results found that all three intubation procedures required longer time whereby all procedures took two attempts for each patient. The process of intubation took more than 30 seconds for the first attempt and failed but all cases took about 5 to 10 seconds for second attempts.Conclusion: This has proven that the use of an intubation box and ergonomic screening booth as a device during intubation procedures was not effective. It is suggested that this device should not be continued by paramedics and a proper management plan is needed to provide appropriate and suitable device innovations.International Journal of Human and Health Sciences Supplementary Issue: 2021 Page: S14

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here