TCI : Target Controlled Infusion, or Totally Confused Infusion? Call for an Optimised Population Based Pharmacokinetic Model for Propofol.
Author(s) -
Mats Enlund
Publication year - 2008
Publication title -
upsala journal of medical sciences
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.808
H-Index - 41
eISSN - 2000-1967
pISSN - 0300-9734
DOI - 10.3109/2000-1967-222
Subject(s) - pharmacokinetics , medicine , bolus (digestion) , propofol , plasma concentration , regimen , target controlled infusion , population , intravenous bolus , anesthesia , pharmacology , surgery , environmental health , remifentanil
Different pharmacokinetic models for target controlled infusion (TCI) of propofol are available in the recently launched open TCI systems. There is also a compelling choice to work with either plasma- or effect-site targets. Knowledge about the clinical consequences of different alternatives is of importance. We aimed to illustrate the potential differences in the actual drug delivery/output between three present commercially available and clinically used pharmacokinetic models: the original Marsh model, which is also implemented in the Diprifusor, the "modified Marsh-" and the Schnider models. Simulations were made in the TivaTrainer program (eurosiva.com). Firstly, our standard plasma target regimen was simulated, and secondly an effect-site target of 3.5 microg/mL was chosen. Thirdly, real infusors were used for measuring the time to reach defined predicted effect-site concentrations when aiming at a plasma target of 6 microg/mL. Identical patient characteristics were used in all simulations: male, 170 cm, 70 kg, 40 years of age. Resulting predicted effect-site peak concentrations, and used bolus doses were recorded, as were the resulting plasma over-shoot, and time frames. The plasma target regimen gave predicted effect-site peaks in the different models ranging from 3.6 to 7.2 microg/mL, reached after 2(3/4) to 4 minutes. To reach the same effect-site target, the three models used bolus doses ranging from 68 to 150 mg given during 22 to 46 seconds. The predicted plasma concentration over-shoots varied from 5.0 to 13.4 microg/mL. There were obvious differences between the models in the time taken to reach defined effect-site concentrations. We observed clinically significant different results between the models. The choice of model will make a difference for the patient. To eliminate confusion - not necessarily to improve precision - we call for an optimised population based pharmacokinetic model for propofol - a consensus model!
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom