ORBITAL FLOOR RECONSTRUCTION WITH TITANIUM MESH;
Author(s) -
Muhammad Usman Khalid,
Arshad Mahmood Malik,
Omer Sefvan Janjua
Publication year - 2014
Publication title -
the professional medical journal/the professional medical journal
Language(s) - English
Resource type - Journals
eISSN - 2071-7733
pISSN - 1024-8919
DOI - 10.29309/tpmj/2014.21.03.2152
Subject(s) - enophthalmos , diplopia , medicine , surgery , complication , dystopia , political science , law
Objective: To determine the outcome of orbital floor reconstruction with titaniummesh in terms of diplopia, enophthalmos, dystopia and infection etc. Study design: Descriptivecase series. Place & duration of study: Department of Oral & Maxillofacial Surgery, PunjabMedical College / Allied Hospital Faisalabad. One and Half year from 01-10-12 to 31-03-14.Material and Method: Twenty two patients clinically and radiographically having defect in theorbital floor due to trauma were included in the study. Titanium mesh was used to reconstruct theorbital floor through infraorbital rim incision and secured in place with 5mm micro screws. Thevariables to be analyzed were diplopia, enophthalmos, orbital dystopia and infection. Results: Inour study male gender predominates over female 20/22. Mean age of patients is 29.36 years ±5.21. Diplopia persisted in 2/10 (20%) patients. Enophthalmos persisted in 7/18 (38.8%) patients.dystopia persisted in ¼ (25%) patients. Infection didn’t develop in any of our patient (0%). Visualacuity was not affected in any of the patient (0%). Conclusions: Titanium mesh is a suitablematerial for reconstruction of orbital floor fractures with little complication rate and no donor sitemorbidity.