Influence of reconstruction parameters of positron emission tomograph scanning on the effect of partial volume of the pathological lesion
Author(s) -
E.V. Emel'yanenko,
I.G. Tarutin,
P. A. Belobokov
Publication year - 2021
Publication title -
vescì nacyânalʹnaj akadèmìì navuk belarusì. seryâ fìzìka-tèhnìčnyh navuk
Language(s) - English
Resource type - Journals
eISSN - 2524-244X
pISSN - 1561-8358
DOI - 10.29235/1561-8358-2021-66-3-356-364
Subject(s) - positron emission tomography , gaussian filter , partial volume , imaging phantom , gaussian , computer science , filter (signal processing) , iterative reconstruction , volume (thermodynamics) , algorithm , point spread function , tomography , mathematics , nuclear medicine , biomedical engineering , artificial intelligence , computer vision , physics , optics , medicine , quantum mechanics , image (mathematics)
In this work, the following tasks were solved: to perform a comparative analysis of data processing methods when calculating recovery factors; to evaluate the influence of time-of-flight technology and PSF function on the recovery factor and the forecast of recovery factor deviation for potential pathological foci with a diameter of 6–8 mm; to evaluate the influence of parameters of iterative reconstruction algorithms, Gaussian filter and axial filters on the recovery factor. The calculation of the recovery factors was carried out on the basis of quantitative characteristics obtained in the analysis of reconstructions of images of the IEC phantom with six spheres installed inside and filled with a radiopharmaceutical. Eight series of experiments with background / sphere activity ratios 1/3, 1/4, 1/6, 1/8, 1/12, 1/14, 1/16, 1/20 were carried out with the same concentration of activity in the spheres during each separate experiment. The forecast of the effect of the partial volume effect on lesions with a diameter of 6 to 8 mm was carried out, taking into account the used reconstruction algorithms. It is advisable to use the results obtained to harmonize diagnostic protocols for scanning with positron emission tomographs using the input parameters of reconstruction algorithms and filters, which will minimize the error in the quantitative assessment of a radiopharmaceutical when analyzing the dynamics of the development of a pathological process, as well as the response of pathology to therapy.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here