z-logo
open-access-imgOpen Access
EVALUATION OF PERFORMANCE OF BEAM COLUMN JOINT WITH REDUCED BEAM SECTION
Author(s) -
Vinayak Patil,
Mukund Shiyekar,
Milinda Mahajan,
Ali Irfani,
Mohd Moazzam,
Vimala,
Luis Calado,
Jorge Proena,
Miguel Espinh,
Carlo Castiglioni,
Luis Calado,
Jorge Proena,
Miguel Espinha,
Carlo Castiglioni,
C Castiglioni,
L Kanyilmaz,
Calado,
Vayas,
Suresh Dhakal,
Mohamed Moustafa,
M Eatherton,
J F Hajjar,
G G Deierlein,
H Krawinkler,
S Billington,
Ma,
Michael Engelhardt,
Jun Jina,
Sherif El-Tawilb,
Andrew Liewa,
Leroy Gardnerb,
Philippe Blocka,
David Milner,
James Wesevich,
Lisa Nikodym,
Vincent Nasri,
Darell Lawver,
John Mould,
H Moghaddam,
Hajirasouliha,
M Nikoukalama,
Kiarash Dolatshahi,
Dale Perry,
James Mcdonald,
Herbert Saffir,
A Tena-Colunga,
H J Nangullasm- Hernndez,
Xiang Yun,
Leroy Gardner
Publication year - 2020
Publication title -
international journal of engineering sciences and research technology
Language(s) - English
Resource type - Journals
ISSN - 2277-9655
DOI - 10.29121/ijesrt.v9.i7.2020.1
Subject(s) - beam (structure) , structural engineering , plastic hinge , connection (principal bundle) , column (typography) , curvature , hinge , finite element method , joint (building) , work (physics) , section (typography) , computer science , engineering , mechanical engineering , mathematics , geometry , operating system
This study reviews mainly holistic design of PEB structure and comparison of behavior of reduced beam section at beam column sub assemblage. Commercial software based on finite element analysis is used for carrying out mathematical modeling and analysis. In recent construction work it is observed that during conditions like earthquake or cyclone connections fails resulting in to progressive collapse. Also it damages column resulting in failure of strong column weak beam theory. In present work after identifying problem structure is fused at connection by reducing beam cross section at location of connection. This is done by reducing cross section of beam in plan expected to result in shifting of plastic hinge from face of column. Reduced beam sections capacity is calculated by simple calculations and verifying them with moment curvature relationships at desired locations. This will concentrate on failure of fuse and not of connection during load application. Motivation of this study is to improve connection by fulfilling strong column and weak beam theory. This will motivate construction industry to utilize steel structures more often assuring repairing of structure as element failure will be dominant over failure of entire structure

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom