z-logo
open-access-imgOpen Access
INDICATIONS FOR IMPLANTATION AND EFFICIENCY OF CARDIOVERTER-DEFIBRILLATORS IN PATIENTS WITH DILATED CARDIOMYOPATHY
Author(s) -
Е. А. Соловьева,
О В Благова,
В П Седов,
Evgeniya Kogan,
Е. В. Заклязьминская
Publication year - 2019
Publication title -
sibirskij medicinskij žurnal
Language(s) - English
Resource type - Journals
ISSN - 2073-8552
DOI - 10.29001/2073-8552-2019-34-2-54-62
Subject(s) - medicine , cardiology , dilated cardiomyopathy , ejection fraction , implantable cardioverter defibrillator , sudden cardiac death , cardiac resynchronization therapy , cardiomyopathy , heart failure , heart transplantation
Purpose . To assess the frequency and predictors of appropriate shocks of cardioverter-defibrillators in patients with dilated cardiomyopathy (DCM) syndrome and the impact on the total mortality and sudden cardiac death (SCD). Material and Methods . A total of 275 patients with DCM syndrome (average age of 46.8 ± 12.5 years; 185 males and 90 females) were observed. Inclusion criteria were left ventricular (LV) end-diastolic diameter (EDD) more than 5.5 cm and LV ejection fraction (EF) less than 50%. Patients with coronary artery stenosis more than 50% were excluded. Implantable cardioverter-defibrillator (ICD) (n=44) and cardiac resynchronization therapy defibrillator (CRT-D) (n=32) were implanted in 76 (27.6%) patients (53 males and 23 females, average age of 48.9±12.9 years, LV EDD of 6.7±0.8 cm, and LV EF of 28.2±9.9%). A comparison group comprised 199 patients (72.4%) without devices (132 males and 67 females, average age of 46.0±12.3 years, LV EDD of 6.5±0.8 cm, and LV EF of 32.0±10.2%). The average follow-up was 27 (24; 30) months. Results . SCD in patients with DCM syndrome was recorded in 2.9% of cases; the total mortality rate was 18.9%; the rate of death + transplantation was 22.6%. The SCD, total mortality, and death+transplantation rates were 2.6% (4.6/0%), 23.7% (22.7/25.0%), and 32.9% (34.1/31.3%) in patients with devices (ICD/CRT-D) and 3.0%, 17.1%, and 16.6% in patients without devices, respectively. The rate of SCD+appropriate shocks (ASR) was significantly higher in study group: 26.3 vs 3.0% in comparison group (p 0.05) were registered more often. The average LV EF was higher in patients with ASR (34.4±9.7%) in comparison with patients without ASR (25.9±8.8%), р<0.005.  Conclusions . The genetic nature of DCM syndrome is an important predictor of appropriate shocks and an independent selection criterion for ICD/CRT-D implantation. Age, NYHA class, and LV EF did not show prognostic significance. Additional predictors of appropriate shocks were sustained/unsustained VT, low QRS voltage, and the absence of LV hypertrophy signs on the ECG. 

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here