z-logo
open-access-imgOpen Access
Specificity of strength calculation for glued-in steel rods in LVL with unidirectional veneer
Author(s) -
Andrii Bidakov,
Evhenyi Raspopov,
Oksana Pustovoitova
Publication year - 2018
Publication title -
academic journal series industrial machine building civil engineering
Language(s) - English
Resource type - Journals
eISSN - 2518-1106
pISSN - 2409-9074
DOI - 10.26906/znp.2018.51.1315
Subject(s) - rod , laminated veneer lumber , cable gland , structural engineering , connecting rod , beam (structure) , materials science , joint (building) , connection (principal bundle) , enhanced data rates for gsm evolution , composite material , veneer , engineering , mechanical engineering , telecommunications , alternative medicine , pathology , medicine
Design of joints of LVL elements with glued-in steel rods and metal connectors is considered as semi-rigid connection and requires taking of account the compliance. A comparative analysis of the test results of the beams with a metal connector and glued-in steel rods as well as solid beams is made in the paper. Design method of glued-in rods in LVL is proposed and taken into account failure mode. It allows reducing the distance between the axes of the rods as well as the distance from the rod axіs to the edges in the cross section of the beam and increasing the joint strength.