z-logo
open-access-imgOpen Access
Calibration error of laser calorimeter due to the unequal distribution of heat in its receiving element
Author(s) -
K. I. Muntean
Publication year - 2018
Publication title -
vìsnik harkìvsʹkogo nacìonalʹnogo unìversitetu ìmenì v.n. karazìna. serìâ radìofìzika ta elektronìka
Language(s) - English
Resource type - Journals
ISSN - 2311-0872
DOI - 10.26565/2311-0872-2018-29-05
Subject(s) - calibration , transducer , metrology , calorimeter (particle physics) , element (criminal law) , computer science , observational error , measurement uncertainty , mechanical engineering , nuclear engineering , materials science , acoustics , optics , engineering , mathematics , physics , statistics , telecommunications , detector , law , political science
Background: It is well known that the problem of improving the accuracy of measurements is fundamental in metrology and does not lose its relevance, regardless of the successes achieved in its solution. The task of increasing the accuracy of state standards of measurement units is constantly at the center of this problem. The scientific and applied value of the search for ways to solve this problem is increasing significantly in the light of modern requirements for ensuring environmental friendliness and reducing the resource consumption of promising industrial production.Objectives of the work is to study of ways to improve the methodology for taking into account the nonequivalence of replacing an optical signal with an electric one when calibrating calorimetric measuring transducers that are part of state standards for laser energy units.Materials and methods:. Theoretical and experimental thermophysical and mathematical models of the receiving element of the calorimetric measuring transducer are proposed and studied, which, unlike the known models based on the thermally thin plate, allow one to evaluate the effect of the uneven distribution of heat in the receiving element on the calibration error of the calorimetric measuring transducer. The substitution coefficient, according to the model, depends only on the geometry of the receiving element and the time constants of its heating and cooling, which are determined experimentally.Results: Theoretical analysis and experimental verification of the proposed models have confirmed their effectiveness in reducing the systematic calibration error of the measuring transducers.Conclusion: The proposed thermophysical and mathematical models of the receiving element of the calorimetric measuring transducer should be used in the certification practice of the State standards of Ukraine of laser energy units.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here