The development of analytical methods to determine metoclopramide-hydrochloric acid in the standard raw and it compared with pharmaceuticals
Author(s) -
Khawla Salman Abd-Alrassol,
Qutaiba A. Qasim,
Maitham Ali AL-Rikabi,
H. N. K. Al-Salman
Publication year - 2019
Publication title -
international journal of research in pharmaceutical sciences
Language(s) - English
Resource type - Journals
ISSN - 0975-7538
DOI - 10.26452/ijrps.v10i4.1663
Subject(s) - reagent , chemistry , hydrochloric acid , resorcinol , metoclopramide , absorption (acoustics) , orange (colour) , analytical chemistry (journal) , chromatography , molar absorptivity , nuclear chemistry , inorganic chemistry , organic chemistry , materials science , optics , medicine , physics , surgery , food science , composite material , vomiting
The three novel easy, to the prepare and sensitive spectral methods, were used to estimate metoclopramide in both standard and pharmaceuticals. The effective double–electron, was present in the metoclopramide compound helps to interact in an acidic medium with a reagent such as diazetide resorcinol and 8-hydroxyquinoline reagents. The present article was extended to find out three analytical methods with UV-V is the detector. In both A and B methods, two azo-dyes are formed, they are orange-red and red stable and have high water solubility, giving highest absorption values at 415 nm and 485 nm but the C method will depend on a complex colour configuration with the p-benzoquinone reagent, which has a maximum absorption at a wavelength of 285 nm. Beer's law was applied in a range of concentrations between 1 and 10 μg / ml, 2-20 μg / ml and 1-30 μg / ml. The values ​​of the molar absorption factors were (4.1224 × 104, 3.0229 × 104 and 1.7373 × 104) L mol-1cm-1 with a sensitivity of Sandell’s equal to 0.2606 × 10-4, 0.9834 × 10-4 and 0.2568 × 10 - 4 μg cm-2 to methods A, B respectively and LLOD values ​​were 0.255, 0.553 and 0.158 μg / ml to methods A, B and C. LLOQ 0.512, 0.898 and 0.455 μg / ml to methods A, B, C respectively. The constant fixed Kf configuration was also calculated for the colored outputs of the reaction where it was found to be equal to 43.6435 × 108, 54.6261 × 10-8 and 17.29099 × 106 L2 mol-2 to all methods A, B, C respectively. The values ​​of G were calculated based on -43.9293 KJ / mol, -44.3735 and -51.2019. G values, molar absorption factor, Sandell sensitivity, detection limit.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here